Otis Elevator Case Study

The problem with the elevator was the inability of maintaining speed control. The controller was checked and many of the boards were replaced with no success. The customer wanted to have the motors tested before modernization took place to determine the electrical integrity of the windings. It was found in Car # 9 that a field coil was so bad that the coil had almost no magnetic properties.(See test data below). Coil was rewound and the speed control was reestablished.


Elevator Motor

CAR # 9

  12 o’clock 2 o’clock 4 o’clock 6 o’clock 8 o’clock 10 o’clock
Resistance 6.8493 0.0116 7.4354 7.0797 6.5586 7.0305
Impedance 538 58 522 527 529 530
Inductance 857 9687 831 840 842 844
Phase Angle 64 16 62 62 62 64
I/F Ratio -30 -3 -33 -30 -30 -30

Care # 8

  12 o’clock 2 o’clock 4 o’clock 6 o’clock 8 o’clock 10 o’clock
Resistance 7.5077 7.621 7.6514 7.0277 7.6963 7.6812
Impedance 513 572 512 598 568 573
Inductance 817 911 815 949 903 912
Phase Angle 63 63 63 62 61 62
I/F Ratio -35 -34 -36 -35 -35 -36



 